Under 49 CFR 40.129, before verifying a confirmed positive, adulterated, substituted or invalid result and releasing it to the DER, the MRO reviews Copy 2 of the CCF for fatal or correctable errors. The MRO checks that Copy 1 matches Copy 2, that the result is legible and that the certifying scientist signed it, and asks for legible copies of unclear documents. Except as 40.133 allows, the MRO holds a verification interview with the employee in person or by telephone. The MRO then verifies the result as negative, cancelled, or positive or a refusal because of adulteration or substitution.