Under 49 CFR 40.162, when one specimen has several verified non-negative results, the MRO reports them all to the DER. When two separate specimens were sent to the laboratory, both negatives are reported as negative. If one is negative and the other non-negative, only the non-negative result is reported. If both are non-negative, all non-negative results are reported. A first negative result is held until the second specimen result arrives. Special procedures apply when a non-negative result is also invalid.